Explosion-proof Distribution Panels
Explosion-proof Distribution Panels
● Explosion protection to
● Can be used in
Zone 1 and Zone 2
Zone 21 and Zone 22
Class I, Zone 1 and Zone 2
Class I, Division 2, Groups A, B, C, D
● Main switch and branch switch are operated with external rotary actuator.
● Internal wiring to the terminal is finished.
● International brand of explosion-proof terminal blocks.
● Copper-free Aluminium Alloy, powder coated surface.
● Entries plugged. Cable glands on request (see P6/24~39).
● Special requirements on request.
● The intelligent distribution panel is equipped with remote transmission capabilities, supporting intelligent control, interconnection and coordination, data monitoring, and early warning protection, and offers various Internet of Things (IoT) interface options. Intelligent functions can be customized according to user requirements.
IECEx PCET 22.0011X
Ambient temperature range: -60°C ≤ Ta ≤ +40°C (+60°C)
Ex db IIB T6…T4 Gb
Ex db IIB+H₂ T6…T4 Gb
Ex tb IIIC T80°C…T130°C Db
Ambient temperature range: -40°C ≤ Ta ≤ +40°C (+60°C)
Ex db [ia Ga] IIB T6…T4 Gb
Ex db [ib Gb] IIB T6…T4 Gb
Ex db [ia Ga] IIB+H₂ T6…T4 Gb
Ex db [ib Gb] IIB+H₂ T6…T4 Gb
Ex tb IIIC T80°C…T130°C Db
TPS 23 ATEX 089761 0029 X
Ambient temperature range: -60°C ≤ Ta ≤ +40°C (+60°C)
II 2 G Ex db IIB T6…T4 Gb
II 2 G Ex db IIB+H₂ T6…T4 Gb
II 2 D Ex tb IIIC T80°C…T130°C Db
Ambient temperature range: -40°C ≤ Ta ≤ +40°C (+60°C)
II 2 G Ex db [ia Ga] IIB T6…T4 Gb
II 2 G Ex db [ib Gb] IIB T6…T4 Gb
II 2 G Ex db [ia Ga] IIB+H₂ T6…T4 Gb
II 2 G Ex db [ib Gb] IIB+H₂ T6…T4 Gb
II 2 D Ex tb IIIC T80°C…T130°C Db
IECEx; ATEX; CU-TR
EN 60079-0, EN 60079-1, EN 60079-11, EN 60079-31
IEC 60079-0, IEC 60079-1, IEC 60079-11, IEC 60079-31
Low voltage: MAX. 1000V AC 50/60Hz; MAX. 1500V DC
High voltage: 6kV, 10kV, 24kV, 35kV AC 50/60Hz
Max. 2000A
Stainless steel
Copper-free Aluminium Alloy, powder coated surface
Window grey (RAL7040)
MCB (miniature circuit breaker) or MCCB (moulded case circuit breaker)
Note: earth leakage protection on request
MCB (miniature circuit breaker) or MCCB (moulded case circuit breaker)
Note: earth leakage protection on request
International brand of terminal blocks
Red, green, yellow
IP66
M6/M8, M8/M8
-40°C ≤ Ta ≤ +40°C (+60°C); -60°C ≤ Ta ≤ +40°C (+60°C)
Standard M□×1.5 plug (the size of entry hole should be processed in accordance with actual requirements), NPT plug on request
DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P6/24~39
Bottom
Surface type (standard)
Pedestal type (optional)