Explosion-proof Light Fittings for Fluorescent Lamp

  • Explosion protection compliant with CENELEC, IEC, and NEC standards
  • Suitable for hazardous areas:
    • Zone 1 and Zone 2
    • Zone 21 and Zone 22
    • Class I, Zone 1 and Zone 2
    • Class I, Division 1, Groups B, C, D
  • Available in three enclosure types:
    • Type I
    • Type II
    • Type III
  • Available lamp configurations:
    • Type I: T8 18W ×2, LED 9W ×2
    • Type II: T8 36W ×2, LED 18W ×2
    • Type III: T8 58W ×2, LED 28W ×2
  • Optimized luminous flux for improved lighting performance
  • Glass tube designed to withstand 4J impact
  • Enclosure made from copper-free aluminium alloy, powder-coated (RAL1021), corrosion-resistant
  • Built-in electronic ballast with wide voltage input, rapid start, stable performance, and power factor ≥ 0.95
  • Built-in LED driver with CC-CV (constant current–constant voltage) output, power factor ≥ 0.95
  • End-of-lamp-life (EOL) rectification effect protection
  • Emergency function available on request
Explosion Protection

IECEx (Global)

  • Ex db IIB T6 Gb
  • Ex db IIB+H₂ T6 Gb
  • Ex tb IIIC T80°C Db, IP66

ATEX (Europe)

  • II 2G Ex db IIB T6 Gb
  • II 2G Ex db IIB+H₂ T6 Gb
  • II 2D Ex tb IIIC T80°C Db
Certifications & Standards
  • IECEx, ATEX
  • EN 60079-0 / -1 / -31
  • IEC 60079-0 / -1 / -31
Construction & Materials
  • Enclosure: Copper-free aluminium alloy, powder-coated (RAL1021), corrosion-resistant
  • Glass Tube: Toughened glass, 4J impact resistant
  • Fasteners: Stainless steel
  • Optional Accessories:
    • Wire guard (powder-coated carbon steel or stainless steel)
    • External reflector (powder-coated aluminium)
Light Source
  • LED Modules (Integrated):
    • 9W ×2, 18W ×2, 28W ×2
  • Fluorescent Lamps (T8):
    • 18W ×2, 36W ×2, 58W ×2
  • Optimized luminous flux for improved lighting performance(Rated luminous flux values are not included in this specification table.)
  • CRI (Ra): ≥ 80
  • CCT: 5000K
    • Optional: Warm white / Cool white
Electrical
  • Ballast / Driver:
    • Electronic ballast (fluorescent models)
    • LED driver with CC-CV output (LED models)
  • Power factor ≥ 0.95
  • Wide voltage input with stable performance
  • Protection against overcurrent, open circuit, short circuit, and surge
Emergency Function
  • Emergency controller with battery pack
  • Protection against overcharge and over-discharge
  • Emergency Power:
    • LED: 9W ×30%, 18W ×30%, 28W ×30%
    • Fluorescent: 36W ×30%, 58W ×30%
  • Charging Time: 24 hours
  • Emergency Duration:
    • 120 minutes (180 minutes optional)
Electrical Data
  • Voltage: 100–275V AC, 50/60Hz
  • Earthing: M5 (internal & external earth bolts)
Protection & Environment
  • Ingress Protection: IP66
  • Ambient Temperature:
    • -60°C to +55°C (depending on configuration)
Installation
  • Terminals: 3 × 1.5–4 mm² (L + N + PE)
  • Cable Entry:
    • 2 × M25×1.5 (standard)
    • Optional: M20 ×1.5 cable glands
    • Cable gland (optional): DQM-II (Ex d)