BAY51 Series

Explosion-proof Light Fittings for Fluorescent Lamp

  • Explosion protection compliant with CENELEC, IEC, and NEC standards
  • Suitable for hazardous areas:
    • Zone 1 and Zone 2
    • Zone 21 and Zone 22
    • Class I, Zone 1 and Zone 2
    • Class I, Division 1, Groups A, B, C, D
  • Available in single and dual lamp configurations
  • Available with fluorescent and LED lamp options:
    • Fluorescent: 18W ×1, 36W ×1, 58W ×1, 18W ×2, 36W ×2, 58W ×2
    • LED: 9W ×1, 18W ×1, 28W ×1, 9W ×2, 18W ×2, 28W ×2
  • Luminous flux updated according to latest design
    (rated luminous flux removed from specification table)
  • Glass tube designed to withstand 4J impact
  • Enclosure made from copper-free aluminium alloy, powder-coated (RAL1021), corrosion-resistant
  • Built-in electronic ballast with wide voltage input, rapid starting, stable performance, and power factor ≥ 0.95
  • Built-in LED driver with wide voltage input, CC-CV (constant current–constant voltage) output, power factor ≥ 0.95
  • End-of-lamp-life (EOL) rectification effect protection
Explosion Protection

IECEx (Global)

  • Ex d IIC T6 Gb
  • Ex tb IIIC T80°C Db, IP66

ATEX (Europe)

  • II 2G Ex d IIC T6 Gb
  • II 2D Ex tb IIIC T80°C Db, IP66
Certifications & Standards
  • IECEx, ATEX
  • EN 60079-0 / -1 / -5 / -7 / -31
  • IEC 60079-0 / -1 / -5 / -7 / -31
Construction & Materials
  • Enclosure: Copper-free aluminium alloy, powder-coated (RAL1021), corrosion-resistant
  • Glass Tube: Toughened glass, 4J impact resistant
  • Fasteners: Stainless steel
  • Optional accessories:
    • Wire guard (powder-coated carbon steel or stainless steel)
    • External reflector (powder-coated aluminium)
Light Source
  • Fluorescent Lamps (T8):
    • 18W ×1, 36W ×1, 58W ×1
    • 18W ×2, 36W ×2, 58W ×2
  • LED Lamps:
    • 9W ×1, 18W ×1, 28W ×1
    • 9W ×2, 18W ×2, 28W ×2
  • Optimized luminous flux for improved lighting performance
  • CRI (Ra): ≥ 80
  • CCT: 5000K
    • Optional: Warm white / Cool white
Electrical
  • Ballast / Driver:
    • Electronic ballast (fluorescent models)
    • LED driver with CC-CV output (LED models)
  • Power factor ≥ 0.95
  • Wide voltage input, stable performance
Emergency Function (Optional)
  • Emergency controller with battery pack
  • Protection against overcharge and over-discharge
  • Emergency Power:
    • 9W ×30%, 18W ×30%, 28W ×30%
  • Charging Time: 24 hours
  • Emergency Duration:
    • 120 minutes (180 minutes optional)
Electrical Data
  • Voltage: 100–300V AC, 50/60Hz
  • Earthing: M5 (internal & external earth bolts)
Protection & Environment
  • Ingress Protection: IP66
  • Ambient Temperature: -20°C to +55°C
Installation
  • Terminals: 3 × 1.5–4 mm² (L + N + PE)
  • Cable Entry:
    • Single lamp: 2 × M25×1.5
    • Dual lamp: 2 × M25×1.5
    • Cable gland (optional): DQM-I or DQM-II (Ex d)