Back to top
BXJ8050 Series
- Explosion protection compliant with CENELEC, IEC, and NEC standards
- Suitable for hazardous areas:
- Zone 0, Zone 1 and Zone 2
- Zone 21 and Zone 22
- Class I, Zone 1 and Zone 2
- Class I, Division 2, Groups A, B, C, D
- Enclosure made of GRP (glass fibre-reinforced polyester resin), offering excellent corrosion resistance and durability
- Flexible design allowing customization of cable entry size and direction
- Designed for safe and reliable terminal connection in harsh and hazardous environments
Explosion Protection
- IECEx (Global): IECEx CQM 13.0031X
- Ex eb IIC T6…T4 Gb
- Ex ia IIC T6 Ga
- Ex ib IIC T6 Gb
- Ex tb IIIC T80°C Db
- ATEX (Europe): LCIE 13 ATEX 3036X
- II 2 G Ex eb IIC T6…T4 Gb
- II 1 G Ex ia IIC T6 Ga
- II 2 G Ex ib IIC T6 Gb
- II 2 D Ex tb IIIC T80°C Db
Standards & Certifications
- IECEx, ATEX, CU-TR
- EN 60079-0 / -7 / -11 / -31
- IEC 60079-0 / -7 / -11 / -31
Construction & Materials
- Enclosure: GRP (glass fibre-reinforced polyester resin)
- Terminal Blocks: International brand explosion-proof terminal blocks
- Fasteners: Stainless steel
Electrical Data
- Rated Voltage:
- Ex e: Max. 1100V AC/DC
- Ex ia: Max. 36V AC/DC
- Ex ib: Max. 80V AC/DC
- Rated Current:
- Ex e: Max. 80A
- Ex ia: Max. 5A
Protection & Environment
- Ingress Protection: IP66
- Ambient Temperature: -60°C to +60°C (depending on temperature class)
Area Classification
- Suitable for:
- Zones 0, 1 & 2
- Zones 21 & 22