BAY51-Q Series

Explosion-proof Light Fittings for Fluorescent Lamp

  • Explosion protection compliant with CENELEC, IEC, and NEC standards
  • Suitable for hazardous areas:
    • Zone 1 and Zone 2
    • Zone 21 and Zone 22
    • Class I, Zone 1 and Zone 2
    • Class I, Division 2, Groups A, B, C, D
  • Two enclosure types available: Type I and Type II
  • Compatible with T8 fluorescent lamps:
    • 18W × 1, 36W × 1, 18W × 2, 36W × 2
  • Enclosure made of glass fiber reinforced polyester (GRP) with polycarbonate diffuser, corrosion-proof
  • Ex e enclosure with explosion-proof internal components
  • Safety interlock between enclosure and diffuser, switches off on opening
  • Built-in electronic ballast with power factor ≥ 0.95
  • Emergency unit with protection against overcharge and over-discharge
  • End-of-lamp-life (EOL) rectification effect protection
Explosion Protection
  • Gas: II 2 G Ex d e q IIC T4 Gb
  • Dust: II 2 D Ex t IIIC T80°C Db IP66
  • Certifications:
    • LCIE 12 ATEX 3045X
    • IECEx COM 07.0007
    • RLC-CN F05.8.00344 (CU-TR)
    • TÜV CY 18 ATEX 02027X; IECEx COM 12.0002X; CU-TR
Conformity to Standards
  • EN 60079-0, EN 60079-1, EN 60079-5, EN 60079-7, EN 60079-31
  • IEC 60079-0, IEC 60079-1, IEC 60079-5, IEC 60079-7, IEC 60079-31
Material
  • Enclosure: GRP, high impact resistance, corrosion-proof
  • Diffuser: Polycarbonate, 90% light transmission, impact resistant
  • Ballast: Electronic ballast with protection against short circuit, overload, lamp aging, and lamp damage
Construction
  • Exposed fasteners: Stainless steel
  • Interlock: BZX4 explosion-proof distance switch, switches off when opened
Lamp Details
  • Lamp type: T8 fluorescent tube (supplied with fittings)
  • Power options:
    • 36W × 2 / 18W × 2
    • 36W × 1 / 18W × 1
Emergency Lighting (where applicable)
  • Emergency power: 36W × 1 / 18W × 1
  • Emergency starting time: 0.3 s
  • Charging time: 24 h
  • Emergency lighting duration: 120 min (180 min optional)
Electrical
  • Rated voltage: 96–254V AC
  • Frequency: 50/60Hz
Protection & Environment
  • Degree of protection: IP66 (IP67 optional)
  • Ambient temperature: -20°C to +55°C
Installation
  • Terminals: 3 × 1.5–4 mm² (L + N + PE)
Cable Entries
  • Standard configuration:
    • 4 × Ø26
    • 2 × M25 × 1.5 cable glands
    • 2 × M25 × 1.5 plugs
  • Thread specification: DQM I/I
  • Pole-mounted version:
    • 1 × M25 cable gland
    • Top cable gland not provided
  • Available cable outer diameter: Ø9–Ø16 mm
Safety Features
  • Safety interlock system switches off power when enclosure is opened
  • End-of-lamp-life (EOL) protection
  • Protection against overcharge and over-discharge