Warom

WAROM Technology MENA FZCO

Total, custom solution provider, offering full scope of WAROM brand and services to our clients in the Middle East and North Africa, with singular focus on the needs of our client

Plot No.S10103, Jebel Ali Free Zone,
Dubai, UAE, P.O.Box 263667

Back to top

HRY97 Series

Light Fittings for Fluorescent Lamp

● Explosion protection to

  • CENELEC
  • IEC
  • NEC

● Can be used in
Zone 1 and Zone 2
Zone 21 and Zone 22
Class I, Zone 1 and Zone 2
Class I, Division 1, Groups B, C, D

● Three enclosure types: Type I, Type II and Type III

● Available lamp and power
Type I: 20W
Type II: 40W, 20W with emergency, 40W with emergency
Type III: 60W, 60W with emergency

● Enclosure in Copper-free Aluminium Alloy, powder coated surface, yellow (RAL1021)

● Built-in LED driver, wide voltage input, CC-CV (constant current – constant voltage) output, power factor ≥0.95

● The lamps can be equipped with emergency device. There are two options for emergency duration: 90min and 180min. Standard configuration is 90min

Explosion protection
Global (IECEx)

IECEx CQM 24.0001X

Gas and dust

Ex db eb mb IIC T5/T4 Gb
Ex tb IIIC T70°C/T90°C Db

Europe (ATEX)

TÜV CY 25 ATEX 0207222 X

Gas and dust

II 2 G Ex db eb mb IIC T5/T4 Gb
II 2 D Ex tb IIIC T70°C/T90°C Db

See Selection Table

Certificates

IECEx; ATEX

Conformity to standards

EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-18, EN 60079-31
IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-18, IEC 60079-31

Material
Enclosure

Copper-free Aluminium Alloy, powder coated surface, yellow (RAL1021)

Diffuser

Polycarbonate, stands 4J impact

LED driver

Wide voltage input, CC-CV (constant current – constant voltage) output, with function of distributed current, constant current, surge-proof and anti-electromagnetic interference, and protection against overcurrent, open circuit, and short circuit

Exposed fastener

Stainless steel

Lamp
Lamp specification

LED module (supplied with the light fittings)

Lamp power (W)

20W, 40W, 60W

Colour rendering index (Ra)

≥80

LED Colour temperature (CCT)

5000K
Note: nature white is available in general. Warm white or cool white is optional, please specify when ordering

Rated voltage

100-277V AC 50/60Hz; 130-250V DC

Earthing protection

M4 (internal & external earth bolts)

Degree of protection

IP66

Ambient temperature

-40°C ~ +60°C (+58°C) (+40°C)
See Selection Table

Terminal

3×1.5~4mm² (L+N+PE)

Cable entries

2×M25×1.5 plugs

Emergency data
Emergency unit

Special emergency controller and battery pack, with protection against overcharge and overdischarge

Emergency power (W)

20W×70%, 40W×35%, 60W×23%

Emergency starting time

0.3s

Charging time

24h

Emergency lighting time

90min (180min is optional)

Battery

Ni-Cd (Ni-MH is optional)