HRMD92 Series

Explosion-proof Distribution Equipment’s

  • Explosion protection compliant with CENELEC, IEC, and NEC standards
  • Suitable for hazardous areas:
    • Zone 1 and Zone 2
    • Zone 21 and Zone 22
    • Class I, Zone 1 and Zone 2
    • Class I, Division 1, Groups B, C, D
  • Designed with flameproof enclosure (Ex d IIB+H₂), suitable for use as feed distribution equipment in control and distribution systems
  • Applicable for main circuit control, branch circuit control, terminal boxes, and motor starting boxes
  • Enclosure made of stainless steel, providing excellent corrosion resistance
  • Equipped with a specialized hinge structure, protecting flameproof joints and extending service life
  • Designed for flexible installation and efficient system integration
  • Custom configurations available upon request
Explosion Protection
  • IECEx (Global): IECEx CML 19.0176X
    • Ex db IIB + H₂ T6 Gb
    • Ex tb IIIC T80°C Db IP66
    • Multiple configurations available depending on specification type
  • ATEX (Europe): CML 19 ATEX 1482X
    • II 2 G Ex db IIB + H₂ T6 Gb
    • II 2 D Ex tb IIIC T80°C Db IP66
    • Additional configurations based on enclosure type

Standards & Certifications

  • IECEx, ATEX, CU-TR
  • EN 60079-0 / -1 / -11 / -31
  • IEC 60079-0 / -1 / -11 / -31
Construction & Materials
  • Enclosure: Stainless steel
  • Fasteners: Stainless steel
Built-in Components
  • Measuring instruments: ammeters, voltmeters, power meters, tachometers, temperature controllers
  • Control devices: switches, disconnectors
  • Protection devices: MCCBs, MCBs, contactors, relays (thermal, time, intermediate)
  • Automation: PLCs, frequency converters, soft starters
  • Electrical accessories: terminals, busbars, resistors, fuses
  • Monitoring & safety: surge protectors, safety barriers, motor protection devices
  • Auxiliary systems: UPS, industrial computers, timers, counters, solid-state relays

Electrical Data

  • Rated Voltage:
    • Max. 1000V AC, 50/60Hz
    • Max. 1500V DC
  • Rated Current: Max. 2000A
Protection & Environment
  • Degree of Protection: IP66
  • Ambient Temperature: -60°C to +60°C
Installation
  • Cable Entries: Standard metric thread (M×1.5); NPT plug available on request
  • Cable Gland (optional): DQM-II (Ex d) or DQM-III (Ex d) recommended
  • Entry Direction: Bottom
  • Mounting: Surface type (standard), pedestal type (optional)

Area Classification

  • Suitable for:
    • Zones 1 & 2
    • Zones 21 & 22